Method 3B
Gas Analysis for the Determination of Emission Rate Correction Factor or Excess Air
40 CFR Part 60, Appendix A-2
From the method — regulatory text
Sections 1.0 and 2.0 of Method 3B—Gas Analysis for the Determination of Emission Rate Correction Factor or Excess Air, as published at 40 CFR Part 60, Appendix A-2. Retrieved 10/07/2026. The full method is on the eCFR.
1.0 Scope and Application
1.1 Analytes.
| Analyte | CAS No. | Sensitivity |
|---|---|---|
| Oxygen (O2) | 7782-44-7 | 2,000 ppmv. |
| Carbon Dioxide (CO2) | 124-38-9 | 2,000 ppmv. |
| Carbon Monoxide (CO) | 630-08-0 | N/A. |
1.2 Applicability. This method is applicable for the determination of O2, CO2, and CO concentrations in the effluent from fossil-fuel combustion processes for use in excess air or emission rate correction factor calculations. Where compounds other than CO2, O2, CO, and nitrogen (N2) are present in concentrations sufficient to affect the results, the calculation procedures presented in this method must be modified, subject to the approval of the Administrator.
1.3 Other methods, as well as modifications to the procedure described herein, are also applicable for all of the above determinations. Examples of specific methods and modifications include: (1) A multi-point sampling method using an Orsat analyzer to analyze individual grab samples obtained at each point, and (2) a method using CO2 or O2 and stoichiometric calculations to determine excess air. These methods and modifications may be used, but are subject to the approval of the Administrator.
1.4 Data Quality Objectives. Adherence to the requirements of this method will enhance the quality of the data obtained from air pollutant sampling methods.
2.0 Summary of Method
2.1 A gas sample is extracted from a stack by one of the following methods: (1) Single-point, grab sampling; (2) single-point, integrated sampling; or (3) multi-point, integrated sampling. The gas sample is analyzed for percent CO2, percent O2, and, if necessary, percent CO using an Orsat combustion gas analyzer.
EssentialRegs notes
Our plain-English reading of Method 3B. Not the method text.
What it measures
The oxygen, carbon dioxide and carbon monoxide content of a stack gas, and from them an emission rate correction factor or the percent excess air.
How it works
A gas sample is pulled from the stack and analyzed with an Orsat-type analyzer, which works by chemical absorption. The sample is passed through reagents that take up carbon dioxide, oxygen and carbon monoxide in turn, and the volume lost shows the share of each. The results are used to calculate a correction factor that adjusts a measured emission rate to a common basis, or to calculate excess air.
Equipment
A sampling probe and collection bag or container, and an Orsat-type gas analyzer with absorbing reagents.
When a rule cites it
Performance tests where a rule requires the measured emission rate to be adjusted by a correction factor from the combustion gas composition, and where the percent excess air is needed.
Notes for compliance staff
Method 3B differs from Method 3 in that it also measures carbon monoxide and gives the correction factor and excess air as its results. Method 3A covers oxygen and carbon dioxide by instrumental analyzer.
Cited by
Provisions in the corpus whose text cites Method 3B. Subscribers land on the provision in the regulation reader; visitors see a preview of it (the GP05 sample opens in full).
40 CFR Part 60 Subpart IIII
- Table 7 to Subpart IIII of Part 60 — Requirements for Performance Tests for Stationary CI ICE With a Displacement of ≥30 Liters per Cylinder
40 CFR Part 60 Subpart JJJJ
- Table 2 to Subpart JJJJ of Part 60 — Requirements for Performance Tests
40 CFR Part 60 Subpart OOOO
40 CFR Part 60 Subpart OOOOa
40 CFR Part 60 Subpart OOOOb
40 CFR Part 60 Subpart OOOOc
40 CFR Part 63 Subpart ZZZZ
- Table 4 to Subpart ZZZZ of Part 63 — Requirements for Performance Tests
The sections marked as regulatory text above are reproduced from the CFR. Everything under ‘EssentialRegs notes’ is our reference copy, not the method. The method as published in the CFR controls.