Gas Analysis for the Determination of Dry Molecular Weight

40 CFR Part 60, Appendix A-2

Read the method on the eCFR →

From the method — regulatory text

Sections 1.0 and 2.0 of Method 3—Gas Analysis for the Determination of Dry Molecular Weight, as published at 40 CFR Part 60, Appendix A-2. Retrieved 10/07/2026. The full method is on the eCFR.

1.0 Scope and Application

1.1 Analytes.

AnalytesCAS No.Sensitivity
Oxygen (O2)7782-44-72,000 ppmv.
Nitrogen (N2)7727-37-9N/A.
Carbon dioxide (CO2)124-38-92,000 ppmv.
Carbon monoxide (CO)630-08-0N/A.

1.2 Applicability. This method is applicable for the determination of CO2 and O2 concentrations and dry molecular weight of a sample from an effluent gas stream of a fossil-fuel combustion process or other process.

1.3 Other methods, as well as modifications to the procedure described herein, are also applicable for all of the above determinations. Examples of specific methods and modifications include: (1) A multi-point grab sampling method using an Orsat analyzer to analyze the individual grab sample obtained at each point; (2) a method for measuring either CO2 or O2 and using stoichiometric calculations to determine dry molecular weight; and (3) assigning a value of 30.0 for dry molecular weight, in lieu of actual measurements, for processes burning natural gas, coal, or oil. These methods and modifications may be used, but are subject to the approval of the Administrator. The method may also be applicable to other processes where it has been determined that compounds other than CO2, O2, carbon monoxide (CO), and nitrogen (N2) are not present in concentrations sufficient to affect the results.

1.4 Data Quality Objectives. Adherence to the requirements of this method will enhance the quality of the data obtained from air pollutant sampling methods.

2.0 Summary of Method

2.1 A gas sample is extracted from a stack by one of the following methods: (1) single-point, grab sampling; (2) single-point, integrated sampling; or (3) multi-point, integrated sampling. The gas sample is analyzed for percent CO2 and percent O2. For dry molecular weight determination, either an Orsat or a Fyrite analyzer may be used for the analysis.

EssentialRegs notes

Our plain-English reading of Method 3. Not the method text.

What it measures

The carbon dioxide and oxygen content of a stack gas, and from them the dry molecular weight of the gas.

How it works

A gas sample is pulled from the stack, either as a single grab sample or as a sample collected over the test period, and analyzed for carbon dioxide and oxygen with an Orsat or Fyrite-type absorption analyzer. The analyzer works by chemical absorption: the sample is passed through reagents that take up each gas in turn, and the volume lost shows the share of each. The remainder of the dry gas is treated as nitrogen. The result is used to calculate the dry molecular weight of the stack gas.

Equipment

A sampling probe and collection bag or container, and an Orsat or Fyrite-type absorption analyzer with absorbing reagents.

When a rule cites it

Performance tests, where the dry molecular weight of the gas is needed to calculate stack gas velocity and flow rate. It is also the way a rule gets oxygen and carbon dioxide values to convert a concentration to a stated reference oxygen level or to a combustion-based emission factor.

Notes for compliance staff

Method 3 is written for combustion-type gas streams, where oxygen, carbon dioxide and nitrogen account for nearly all of the dry gas. Streams that contain methane or other major components call for Method 3C. When oxygen and carbon dioxide are read by an instrumental analyzer instead, the method is Method 3A.

Cited by

Provisions in the corpus whose text cites Method 3. Subscribers land on the provision in the regulation reader; visitors see a preview of it (the GP05 sample opens in full).

Regulation 4

Regulation 6

  • II.E.3. — Method 3 for gas analysis to be used when applying Reference Methods 5 and 6;
  • III.E.3. — Method 3 for gas analysis to be used when applying reference Methods 5 and 6;
  • IV.D.3. — Method 3 for gas analysis to be used when applying Method 6; and

40 CFR Part 60 Subpart IIII

40 CFR Part 60 Subpart JJJJ

40 CFR Part 63 Subpart ZZZZ

49 CFR Part 192

  • § 192.624(c)(3)
  • § 192.632 — Engineering Critical Assessment for Maximum Allowable Operating Pressure Reconfirmation: Onshore steel transmission pipelines.