EssentialRegs

Regulation 4

5.1.1.

Appendix A — Test Method Protocols for Measuring Wood-Burning Masonry Heater Emissions › 5.0. TESTING

Regulation 4 5.1.1. is in the full corpus.

Start your 7-day trial to open it in the cross-referenced reader.

Code of Colorado Regulations · Regulation Number 4

SALE AND INSTALLATION OF WOOD-BURNING APPLIANCES AND THE USE OF CERTAIN WOOD BURNING APPLIANCES DURING HIGH POLLUTION DAYS 5 CCR 1001-6

View official source ↗

A preview of Code of Colorado Regulations · Regulation Number 4 — its structure, and a few AI-generated plain-English summaries. The full cross-referenced text is available to subscribers.

What's inside

  • PART AAPPLICABILITY
  • PART BSALE, INSTALLATION AND USE OF WOOD-BURNING APPLIANCES
  • PART CSTATEMENTS OF BASIS, SPECIFIC STATUTORY AUTHORITY AND PURPOSE
  • Appendix ATest Method Protocols for Measuring Wood-Burning Masonry Heater Emissions
  • 1.0.SCOPE
  • 2.0.DEFINITIONS
  • 3.0.APPROVAL PROCEDURES
  • 3.1.
  • 3.1.1.
  • 3.1.2.
  • 3.2.
  • 3.2.1.
  • 3.2.2.
  • 3.2.2.1.
  • 3.2.3.
  • 3.2.4.
  • 3.2.5.
  • 3.2.6.
  • 3.3.
  • 3.4.Permanent Label, Temporary Label, and Owner's Manual.
  • 3.4.1.
  • 3.4.2.
  • 3.4.3.
  • 3.4.4.
  • 3.5.Emissions Control Devices.
  • 3.5.1.
  • 3.5.2.
  • 3.5.3.
  • 3.5.3.1.
  • 3.6.
  • 4.0.TEST LABORATORY ACCREDITATION
  • 4.1.
  • 5.0.TESTING
  • 5.1.
  • 5.1.1.
  • 5.2.
  • 5.2.1.
  • 5.2.2.
  • 5.2.3.
  • 5.2.4.
  • 5.3.
  • 5.3.1.
  • 5.3.2.
  • 5.3.3.
  • 5.3.4.
  • 5.3.5.
  • 5.3.6.
  • 5.3.7.
  • 5.3.8.
  • 5.3.9.
  • 5.3.10.
  • 5.3.11.
  • 5.3.11.1.
  • 5.3.11.2.
  • 5.3.11.3.
  • 5.3.11.4.
  • 5.3.11.5.
  • 5.3.11.6.
  • 5.3.11.7.
  • 5.3.12.
  • 5.3.13.Vacuum Gages. Vacuum gage with a range of 0 to 30 inches of mercury.
  • 5.3.14.
  • 5.3.14.1.
  • 5.3.14.2.
  • 5.3.14.3.
  • 5.3.14.4.
  • 5.3.14.5.
  • 5.3.14.6.
  • 5.4.Sampling Supplies and Reagents.
  • 5.4.1.
  • 5.4.2.
  • 5.4.3.Methanol. Reagent Grade or better. (Report blanks for each supply batch.)
  • 5.4.4.
  • 5.4.5.
  • 5.5.Test Fuel.
  • 5.5.1.Species. Test fuel shall be Douglas fir.
  • 5.5.2.
  • 5.5.2.1.
  • 5.5.3.
  • 5.5.4.
  • 5.5.4.1.
  • 5.5.5.
  • 5.5.5.1.
  • 5.5.5.2.
  • 5.5.5.2.1.
  • 5.5.5.2.2.
  • 5.5.5.2.3.
  • 5.5.5.3.
  • 5.5.5.4.
  • 5.5.5.5.
  • 5.5.5.6.Fuel-Crib Volume (Fcv). Calculate the fuel-crib volume (Fcv) as 30.0% of the Fv.
  • 5.5.5.6.1.
  • 5.5.5.7.
  • 5.5.5.8.
  • 5.5.6.
  • 5.5.7.First Fuel-Crib Structure.
  • 5.5.7.1.
  • 5.5.7.2.
  • 5.5.7.3.
  • 5.5.8.
  • 5.5.9.
  • 5.5.10.
  • 5.5.11.
  • 5.5.12.Kindling.
  • 5.5.12.1.
  • 5.5.12.1.1.
  • 5.5.12.1.2.
  • 5.5.12.1.3.
  • 5.5.12.1.4.
  • 5.5.12.1.5.
  • 5.5.12.2.
  • 5.5.12.3.
  • 5.5.12.4.
  • 5.6.Calibration and Audit Requirements.
  • 5.6.1.
  • 5.6.2.
  • 5.6.3.
  • 5.6.4.
  • 5.6.5.
  • 5.6.6.
  • 5.6.7.
  • 5.6.8.
  • 5.6.8.1.
  • 5.6.8.2.
  • 5.7.Test Preparations.
  • 5.7.1.
  • 5.7.2.
  • 5.7.3.
  • 5.7.3.1.
  • 5.7.3.1.1.
  • 5.7.4.
  • 5.7.5.
  • 5.7.5.1.
  • 5.7.5.2.
  • 5.7.5.2.1.
  • 5.7.5.2.2.
  • 5.7.6.
  • 5.7.6.1.
  • 5.7.6.2.
  • 5.7.7.ESS Pre-Test Set-Up.
  • 5.7.7.1.
  • 5.7.7.2.
  • 5.8.Masonry Heater Operation and Testing Protocols.
  • 5.8.1.
  • 5.8.2.Pre-Test Procedures.
  • 5.8.2.1.
  • 5.8.2.2.
  • 5.8.2.3.
  • 5.8.3.
  • 5.8.4.
  • 5.8.5.
  • 5.8.6.
  • 5.8.7.
  • 5.8.8.
  • 5.8.8.1.
  • 5.8.8.2.
  • 5.8.8.2.1.
  • 5.8.9.
  • 5.8.10.
  • 5.8.11.
  • 5.8.12.
  • 5.8.12.1.
  • 5.8.13.Post-Test Procedures.
  • 5.8.13.1.
  • 5.8.13.2.
  • 5.8.13.3.
  • 5.8.13.4.
  • 5.8.13.5.
  • 5.8.14.
  • 5.8.14.1.
  • 5.8.14.2.
  • 5.8.14.2.1.
  • 5.8.14.3.
  • 5.8.14.3.1.
  • 5.8.14.4.
  • 5.8.14.5.
  • 5.8.14.6.
  • 5.8.14.7.
  • 6.0.CALCULATIONS
  • 6.1.
  • 6.2.
  • 6.3.Particulate Emissions.
  • 6.3.1.
  • 6.3.1.1.
  • 6.3.2.
  • 7.0.REPORTING REQUIREMENTS
  • 7.1.
  • 7.2.
  • 7.3.
  • 7.4.
  • 7.5.
  • 7.6.
  • 7.6.1.Introduction.
  • 7.6.1.1.Purpose of Test. Colorado APCD-approval or audit.
  • 7.6.1.2.
  • 7.6.1.3.
  • 7.6.1.4.
  • 7.6.1.5.
  • 7.6.2.Summary and Discussion of Results.
  • 7.6.2.1.
  • 7.6.2.2.
  • 7.6.2.3.
  • 7.6.3.Process Description.
  • 7.6.3.1.
  • 7.6.3.2.
  • 7.6.3.3.
  • 7.6.3.4.
  • 7.6.3.5.
  • 7.6.4.
  • 7.6.5.
  • 7.6.5.1.
  • 7.6.6.Quality Control and Quality Assurance (QC/QA) Procedures and Results.
  • 7.6.6.1.Calibration Records. Description of calibration procedures and results.
  • 7.6.6.2.
  • 7.6.7.Appendices.
  • 7.6.7.1.
  • 7.6.7.2.
  • 7.6.7.3.
  • 7.6.7.4.
  • 7.6.7.5.
  • 7.6.7.6.
  • 7.6.7.7.
  • 7.6.7.8.
  • 7.6.7.9.
  • 7.6.8.
  • 7.6.8.1.
  • 7.6.8.2.
  • 7.6.8.3.
  • 7.6.8.4.
  • Editor’s Notes

Plain-English summaries

Code of Colorado Regulations · Regulation Number 4

SALE AND INSTALLATION OF WOOD-BURNING APPLIANCES AND THE USE OF CERTAIN WOOD BURNING APPLIANCES DURING HIGH POLLUTION DAYS 5 CCR 1001-6

Colorado Regulation Number 4 governs the sale and installation of wood-burning appliances and restricts the use of certain wood-burning appliances during high pollution days.

I.A.4.

A boiler is a domestic solid wood-burning appliance used mainly to heat the space where it sits by circulating a heated gas or fluid through pipes, and it must be tested and listed as a boiler under accepted U.S. or Canadian safety testing codes.

I.A.5.

Burn down time is the period – no more than three hours after a high pollution day is declared – allowed for combustion to stop in any wood-burning stove, pellet stove, masonry heater or wood-burning fireplace under this regulation.

I.A.8.

An exempt device is a wood-burning device that does not meet EPA's definition of a wood-burning stove under 40 CFR Part 60 Subpart AAA (2015) and is also not a fireplace, masonry heater, or pellet stove as defined in this regulation.

I.A.9.

A furnace is a solid wood-burning appliance designed to sit outside normal living areas and heat other spaces by blowing heated air through ducts. It must be tested and listed as a furnace under accepted U.S. or Canadian safety codes.

Read the full text of Code of Colorado Regulations · Regulation Number 4

Subscribers get the full text, linked cross-references, and plain-English summaries as they pass the automated check against source text — $10 / month or $100 / year.